Project type
Lighting for Guestrooms, Lobbies and Corridors
Specification rep for hospitality lighting: guestrooms, lobbies and corridors from the SESCO line card, across South Florida.
Need lighting priced, or just need to know if I can get it? Send me the project or ask me a question. No charge for a takeoff.
myCreation 3D-printed luminaires
Lightolier and Day-Brite track heads, cylinders, decorative pendants, low bays and high bays printed to order in Littlestown, PA from at least 75 percent recycled or bio-circular polycarbonate, in eight satin colors and a dozen textures, with logo options and the spec sheets for all eleven series. See the myCreation page →
Wattstopper controls, matched to the Florida energy code
Each mandatory lighting-control requirement in the Florida Building Code, Energy Conservation, mapped to the DLM, wireless and standalone Wattstopper part that satisfies it, with part numbers. See the Wattstopper page →
Hospitality lighting is bought differently from residential lighting. Quantities are large, finishes have to match across an entire floor, fixtures have to survive housekeeping and guests who have no reason to be gentle, and every piece has to clear accessibility and listing requirements before it is approved for the job. Send me the project and I will price what I can cover from the lines I represent.
I work from a schedule. Send the fixture list and I will confirm what I represent, price the quantities, flag anything with a listing or projection problem, coordinate finish samples across manufacturers, and quote attic stock in the same order so replacements match years later. Where a substitution makes sense I propose it with a reason attached. Reach me at 786-395-1222 or start at the request a quote page.
Guestroom Layers and Guest-Proof Controls
A guestroom needs five things lit: the entry, the general volume, the bed for reading, a work surface, and the bath. Reading light is where most rooms fail. A bedside fixture with a tight beam or a shielded shade lets one guest read while the other sleeps, while an open shade over a nightstand does the opposite. Confirm on the spec sheet whether a bedside sconce includes a switch, a receptacle or USB, since that varies by manufacturer and even within one family.
Controls should be legible at two in the morning to someone who has never been in the room. A clearly marked master off at the bed is worth more than a scene system nobody learns. Keep every fixture in the room at one nominal color temperature, generally 2700K for a warm guestroom, and choose the dimming protocol before the dimmer so drivers and controls are matched rather than discovered on site.
Corridors, Public Space and Accessibility
Corridor sconces sit on a circulation path, so the ADA standards apply: a wall-mounted fixture whose leading edge falls between 27 and 80 inches above the floor may not project more than four inches from the wall. That one rule eliminates a large share of attractive residential sconces from hotel corridors. Space the remaining candidates for even scallops with no dark gap at guestroom doors, and keep egress and emergency lighting as its own code-driven system rather than leaning on the decorative layer.
Public spaces are sized to volume, not to floor plan. A fixture that reads correctly in a ten-foot room disappears in a two-story lobby, and a chandelier chosen from a catalog photograph often arrives smaller than the space needs. Check sightlines from stairs and mezzanines, because open-top fixtures that look clean from below show their lamps from above. Ask how the fixture will be reached for cleaning and relamping before it is approved.
Finish Matching, Ordering and Attic Stock
Finish names are not standardized. One manufacturer's bronze is another's oil-rubbed brown, and two fixtures approved from small chips can look wrong side by side on a wall. Request physical samples and approve them together under the light the project will actually use. Order a full run at once so pieces come from the same finishing batch, and buy attic stock in that order rather than a year later. Confirm voltage and location listing on imported lines before the purchase order goes out.
Common questions
Do you sell lighting for hotel and contract projects?
Yes. Send me the project and I will price what I can cover from the lines I represent. Send me the project or a cut sheet package and I will price what I represent, note anything I cannot supply, and suggest alternates from the same lines. Call 786-395-1222 to reach me.
Can any wall sconce be used in a hotel corridor?
No. Corridors are circulation paths, so a sconce with its leading edge between 27 and 80 inches above the floor may project no more than four inches from the wall under the ADA standards. Many decorative sconces exceed that. Shallow-profile fixtures, or mounting above 80 inches, are the usual solutions, and I can filter a schedule for it.
Can finishes be matched across different manufacturers?
Only by looking at real samples. Finish names vary by brand and even by production run, so approve physical samples together under the project's own light rather than trusting catalog names. Once approved, order the full quantity at one time so pieces come from the same batch, and include attic stock in that same order.
What color temperature should guestrooms use?
2700K is the common choice for guestrooms because it reads warm and residential. The more important rule is consistency: every fixture in the room, including the bath and any recessed downlights, should share one nominal color temperature. Specify 90 CRI or better and put the room on dimming so guests can set an evening level.
Get project pricing
send me the fixture list, the plan, or just a photo of what you like. I price South Florida projects line by line from the SESCO card, and I will tell you who holds anything that is not on it.
Request a quote786-395-1222Manufacturers in this category
These are the lines on my card that I specify for hotel and hospitality lighting. Every manufacturer in my index, with who represents each one in South Florida, is in the manufacturer index.
Not seeing the line you were specified? Search all 639 manufacturers or look up the rep for your territory. I quote lines beyond the ones listed here.
Lines often specified for lighting
7 of the 163 SESCO lines cover this category. Any of them can be priced from your fixture schedule.
Besa Lighting · DMF Lighting · Hunter · L'Originale · Lightolier 3D Printed · Luxxbox · Panzeri
Not seeing a line? The full manufacturer index covers the whole market, or just send me the project. See hospitality projects I have worked on.
Related: Restaurant and bar lighting · Retail store lighting · Chandeliers · Wall sconces · Living room lighting
Ask me about lighting
Not ready for a full quote? Ask the question — whether the line holds a spec, what the lead time looks like, or what I would put up as an alternative. I usually come back the same business day.
Or call 786-395-1222, Monday to Friday, nine to five. If you have drawings or a fixture schedule to attach, use the quote form instead.